Newert

Apps · Newert Health

Newert Health

An app for connecting supported devices, monitoring individual and group biosignals, and reviewing period trends, analysis reports, and raw or biomarker CSV files.

Product overview

What does it measure and what do you get?

Primary use

Individual and group metrics

Review measurement status and supported heart, HRV, activity, and fitness metrics for connected participants.

Interfaces

Mobile app + web console

Connect devices in the mobile app, then monitor multiple participants and detailed results in the web console.

Availability

With EmoConnect PRO

Newert Health is not a separate free edition. It is used with an active EmoConnect PRO subscription.

Who this is for

Principal investigators

Use it when you need one view of measurement progress and key biomarkers across multiple participants.

Field operators

Use it to check participant connections, battery, measurement status, and supported route information during a session.

Data analysts

Use it when raw sensor files and calculated biomarker files must be separated for downstream analysis.

How to measure

Use Newert Health in five steps

Follow the actual mobile and web-console flow. Available metrics may vary with the connected device and measurement conditions.

Before you start · Prepare these four items before measuring

Checking the account and permissions first prevents most device-discovery and file-saving questions.

01

Supported device

Review the available EmoConnect, BioLink Band, or Apple Watch connection option in the app. Available metrics vary by device.

02

PRO account

Sign in with a Newert Health account that has active EmoConnect PRO access.

03

Bluetooth and permissions

Enable Bluetooth and allow the nearby-device permissions required by the operating system. Review location permission if route features are needed.

04

Group and participant IDs

For multi-user monitoring, add participants to the same group and prepare non-identifying participant codes.

  1. STEP 1

    Sign in and select a device

    Choose the device type in the Newert Health mobile app and refresh the nearby-device list. Confirm the target device name before connecting.

    • Make sure the device is powered on and nearby
    • Disconnect it from any other phone or program
    • Record the device name and participant code
    The public example uses an anonymous account. Device identifiers are shown only as demonstration values.
  2. STEP 2

    Review live group measurement status

    Use Live overview to check each participant's connection, battery, heart rate, RMSSD, steps, and activity intensity in one place.

    • Separate Measuring from Disconnected status
    • Prioritize devices with low battery
    • Use name search and Measuring first sorting
    View measurement progress and key metrics as tiles or a table.
  3. STEP 3

    Open participant metrics and the route view

    Select a participant to review heart rate, SDNN, RMSSD, SpO₂, temperature, activity metrics, and a supported route view.

    • Confirm the selected participant code
    • Check the unit and measurement time for each metric
    • For route data, verify location permission and GPS reception
    Available fields depend on the connected device, sensors, and measurement conditions.
  4. STEP 4

    Review trends and the analysis report

    Select measured days in the calendar and compare daily, weekly, or monthly changes in heart, HRV, SpO₂, temperature, activity, and fitness metrics. Open the analysis report when enough data is available.

    • Confirm that the selected period contains valid measurement days
    • Separate average, maximum, minimum, and first-to-last change
    • Treat scores and risk summaries as measurement summaries, not diagnoses
    Change the period and metric tabs to compare trends.
  5. STEP 5

    Save the CSV required for downstream analysis

    In Settings, check whether raw-sensor and biomarker CSV saving are enabled. In the supplied files, rawData_*.csv and BioMarker_*.csv share the same Record Time. Align them by their Time columns rather than row number.

    • Confirm storage permission and file location
    • For biomarker CSV files, confirm active PRO access
    • Read row one as metadata and row two as the header
    • Align the 0.02-second Raw and one-second BioMarker timelines

Download

Review a sample file first

Check the file structure, columns, and units before measuring so that you can prepare your analysis pipeline in advance.

Basic Raw Data CSV sample

Preview the structure used to store PPG and nine-axis IMU data on one timeline.

Included fields

Time · PPG · ACC x/y/z · Gyro x/y/z · Mag x/y/z · event

This sample removes measurement time and keeps a few rows from the file supplied on August 21, 2026. Row one is Record Time metadata, row two is the header, and samples are 0.02 seconds apart. Trim the leading whitespace that may appear before event in the actual Raw header.

Download basic CSV sample

PRO biomarker CSV sample

Preview the verified 11-column, one-second structure of the user-facing file supplied on August 21, 2026.

Included fields

Time (s) · HR (BPM) · SDNN (ms) · RMSSD (ms) · Steps · 활동 강도 · 활동 시간 · 평균 심박 강도 (%) · 현재 심박 강도 (%) · VO2max (ml/kg) · HRR (bpm)

This anonymous sample removes Record Time and identifying data from the supplied file. Initial zeros remain unchanged rather than being replaced with invented values.

Download PRO CSV sample

Data example

Five outputs are available after measurement

Continue from a live number to group operations, individual trends, reports, and analysis-ready files.

Live group overview

Review participant connection, measurement status, battery, and key metrics together.

Participant details and route

Review individual biomarkers, activity metrics, and a route when location data is enabled.

Period trends and analysis report

Review daily, weekly, or monthly changes and summaries for health, cardiovascular, activity, and fatigue metrics.

Raw Data CSV

Store PPG with accelerometer, gyroscope, and magnetometer values on one timeline.

PRO biomarker CSV

In the supplied file, store HR, SDNN, RMSSD, Steps, activity intensity and duration, average/current HR intensity, VO₂max, and HRR.

The report summarizes measurements as scores and supporting metrics. It is not a medical diagnosis.
Group device locations require appropriate location permission and GPS reception.

Basic Raw Data CSV example rows

PPG, nine-axis IMU, and event values share the same time row. Use this structure for custom preprocessing or your own algorithms.

Time (s)PPG (dB)ACC xACC yACC zGyro xGyro yGyro zMag xMag yMag zevent
0.0224119.000-0.1050.8589.727-0.022-0.011-0.010-50.531-7.3488.3980
0.0424121.918-0.1060.9079.721-0.030-0.024-0.010-50.363-7.0788.2980
0.1024130.673-0.1071.0549.706-0.053-0.063-0.012-49.858-6.2717.9951

PRO biomarker CSV example rows

Row one contains Record Time metadata and the actual header starts on row two. Calculated metrics may be zero during initialization, and activity duration is stored as text such as 0m 0s.

Time (s)HR (BPM)SDNN (ms)RMSSD (ms)Steps활동 강도활동 시간평균 심박 강도 (%)현재 심박 강도 (%)VO2max (ml/kg)HRR (bpm)
10.000.000.000.00-0m 0s0.000.000.000.00
784.9744.3532.660.00-0m 0s42.0042.0023.170.00
1982.7757.2775.500.00-0m 0s38.0041.0023.170.00

Separate raw data from PRO biomarkers

Newert Health is used with EmoConnect PRO. In this table, Basic refers to the raw sensor data available from a standard measurement, while PRO adds a separate calculated-metrics file.

PPG and 9-axis IMU
Basic raw dataPPG, accelerometer, gyroscope, magnetometer, and events
Added with PROAvailable together with raw data
Heart and HRV
Basic raw dataAnalyze the source signal yourself
Added with PROCalculated HR, SDNN, RMSSD, and related metrics
Activity and fitness
Basic raw dataSource accelerometer and related signals
Added with PROSteps, activity intensity and duration, average/current HR intensity, VO₂max, and HRR
Additional columns
Basic raw dataSource output from the connected sensor
Added with PROThe supplied user-facing BioMarker CSV has no SpO₂, temperature, distance, calories, or battery columns
Best for
Basic raw dataCustom preprocessing and algorithm research
Added with PROFaster dashboard review and downstream analysis of calculated metrics

Purchase, download, and adoption

Ask about the right product and adoption path

Tell us your environment and required data scope, and we will guide you to the appropriate product, download, and adoption path.

Contact us about Newert Health

Continue with these guides